Configuring The High-Speed T3 Interface; Configuring The Atm Interfaces - 3Com 3C8S5007 - SuperStack II PathBuilder S500 Switch User Manual

User guide
Table of Contents

Advertisement

62
C
4: B
HAPTER
ASIC
Configuring the
High-Speed T3
Interface
Configuring the
ATM Interfaces
C
P
, P
ONFIGURATION OF
ORTS
This section describes how to configure the high-speed T3/E3 ports for
HSSI, T3-CBIT or M13, and E3 modes of operation.
To configure the high-speed T3 interface for HSSI operation, follow these
steps:
1 Set the connector type for HSSI operation using:
SETDefault !<path> -PAth CONNector = HSSI
2 Set the T3/E3 frame mode using:
SETDefault !<path> -PAth T3E3FrmMode = HSSI
To configure the high-speed T3/E3 interface for T3 operation, follow
these steps:
1 Set the connector type for T3 operation using:
SETDefault !<path> -PAth CONNector = BNC
2 Set the T3/E3 frame mode using:
SETDefault !<path> -PAth T3E3FrmMode = M13 (or CBit)
3 Set the line build output option using:
SETDefault <!path> -PAth T3LineBdout = HIGH
To configure the high-speed E3 interface for HSSI operation, follow these
steps:
1 Set the connector type for E3 operation using:
SETDefault !<path> -PAth CONNector = BNC
2 Set the T3/E3 frame mode using:
SETDefault !<path> -PAth T3E3FrmMode = E3
For more information about the Path Service parameters and settings, see
the Path Service parameters chapter in Reference for Enterprise OS
Software.
This section describes how to configure the ATM interfaces. Using virtual
ports, ATM interfaces can be configured to receive data using permanent
virtual circuits (PVCs), LAN Emulation (LANE), and PPP over ATM.
,