A
G: C
PPENDIX
OMPLETING
ADD !T1CHAN23 -PA ChannelMap 23
ADD !T1CHAN24 -PA ChannelMap 24
#
#
ChannelBaud:
This parameter specifies the baud rate (56K or 64K) of
#
each timeslot (i.e. channel) mapped to the
#
specified path.
#
This setting can be changed to CB56K (56kbits/sec) for
#
leased-line paths that require 56kbit/sec operation
#
#
Some examples on changing the ChannelBaud parameter setting are:
#
#
SETDefault !T1CHAN13 -PAth ChannelBaud = CB56K
#
SETDefault !T1CHAN4A -PAth ChannelBaud = CB56K
# Enable all the paths
SETDefault !4A.1-!4D.24 -PAth Control = Enable
T
U
-WAN C
HE
LTRA
ONFIGURATION
Default setting is CB64K (64kbits/sec).