External AC Power Cables

To avoid electrical shock, a power cable with a grounded attachment plug is provided. Use only properly
grounded outlets.
Power cables used in the United States and Canada are listed by Underwriter's Laboratories (UL) and
certified by the Canadian Standards Association (CSA). These power cords consist of the following:
v Electrical cables, Type SVT or SJT.
v Attachment plugs complying with National Electrical Manufacturers Association (NEMA) 5-15P, that is:
"For 115V operation, use a UL listed cable set consisting of a minimum 14 AWG, Type SVT or SJT
three-conductor cord a maximum of 15 feet in length and a parallel blade, grounding type attachment plug
rated at 15 A, 125V."
"For 230V operation in the United States use a UL listed cable set consisting of a minimum 18 AWG, Type
SVT or SJT three-conductor cable a maximum of 15 feet in length, and a tandem blade, grounding type
attachment plug rated at 15 A, 250V."
v Appliance couplers complying with International Electrotechnical Commission (IEC) Standard 320, Sheet
C13.
Power cables used in other countries consist of the following:
v Electrical cables, Type HD21.
v Attachment plugs approved by the appropriate testing organization for the specific countries where they
are used.
"For units set at 230 V (outside of U.S.): use a cable set consisting of a minimum 18 AWG (1.0 mm²
nominal cross sectional area). Outside of North America, a more common cordage reference is in mm²
and for a HAR (harmonized) cord, you may not find an AWG equivalent.
To find the power cables that are available, refer to Chapter 10, "Parts Information," on page 301.