Firmware Checkpoints - IBM 9114-275 - IntelliStation POWER 275 Service Manual

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

Firmware Checkpoints

Firmware uses checkpoints (progress codes) in the range of Exxx to EFFF. These checkpoints occur
during system startup and can be useful in diagnosing certain problems. Service processor checkpoints
are listed in "Service Processor Checkpoints" on page 106.
If you have a checkpoint with no location code associated with it, see "Determining Location Code" on
page 133. If a checkpoint has a location code associated with a FRU replacement, see "Mapping AIX and
Physical Location Codes" on page 23 for physical location information.
If you replace FRUs and the problem is still not corrected, go to "MAP 1540: Problem Isolation
Procedures" on page 87 unless otherwise indicated in the tables.
Note: If you receive a four-digit code in the range of E1xx to EFFF that is not listed in the table above, go
to "MAP 1540: Problem Isolation Procedures" on page 87.
Table 2. Firmware Checkpoints
Checkpoint
E101
E102
E105
E10A
E10B
E111
E120
E121
E122
E130
E131
E132
E133
E135
E134
E138
114
IntelliStation POWER 9114 Model 275 Service Guide
Description
Create RTAS node
Load/Init RTAS
Transfer control to operating system
(normal boot).
Load RTAS device tree
Set RTAS device properties
GOOD CRC - jump to composite image
Initialize I/O and early memory block
Initialize service processor
RTAS sensor setup complete
Build device tree
Build device tree
Build device tree
Build device tree
Configuring memory nodes
Create memory node
Create options node
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
See "Boot Problems/Concerns" on page
128..
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation power 9114 275

Table of Contents