IBM 9114-275 - IntelliStation POWER 275 Service Manual page 134

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

Table 2. Firmware Checkpoints (continued)
Checkpoint
E174
E175
E176
E177
E17B
E183
E18D
E191
E19A
E19B
E19D
E19E
E1A0
E1A1
116
IntelliStation POWER 9114 Model 275 Service Guide
Description
Establishing host connection
BootP request
TFTP file transfer
Transfer failure due to TFTP error condition See "Boot Problems/Concerns" on page
Processor clock speed measurement
Service processor POST
A system reset request has been sent to
the service processor.
Create ISA reserved node
NVRAM auto-boot? variable not found -
assume FALSE
NVRAM menu? variable not found -
assume FALSE
Create NVRAM node
Real-time clock (RTC) initialization
User requested boot to SMS menus via
keyboard entry
User requested boot to open firmware
prompt via keyboard entry
Action/
Possible Failing FRU
If the system is not connected to an active
network, or if the target server is
inaccessible (which can result from
incorrect IP parameters being specified),
the system still attempts to boot and
because time-out durations are necessarily
long to accommodate retries, the system
may appear to hang.
Restart the system and get to the SMS
utilities menu. Under Select Boot Options,
verify:
v Is the intended boot device correctly
specified in the boot list?
v Are the IP parameters correct?
v Look at the server configuration for this
client.
v Attempt to ping the target server using
the ping utility in SMS.
Follow the repair actions for checkpoint
E174.
Follow the repair actions for checkpoint
E174.
128..
Call service support.
1. Replace the service processor, location:
U0.1-P1-X1.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
1. Check for system firmware updates.
2. Call service support.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Refer to error code 28030xxx in
"Checkpoint and Error Code Index" on page
134..
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
Go to "MAP 1540: Problem Isolation
Procedures" on page 87.

Advertisement

Table of Contents
loading

This manual is also suitable for: