Checkpoint or Error
What You Should Do
Code
1xxx xxxx
System Power Control Network (SPCN) Error Codes
1. There may be additional error codes and information in the service processor error log.
2. Confirm that this is the first error code that caused the failure as described in
3. Did you come to this step from step 2?
2xxx xxxx
Firmware Error Codes
Go to "Firmware Error Codes" on page 142 and follow the instructions in the Firmware Error
Code table.
The system must be powered off to examine the contents of the service processor error
log.
a. Is the system still powered on?
NO
Go to step 2 below.
Yes
Ask the customer if the system can be powered off, then go to substep B.
b. Can the system be powered off?
NO
Go to step 3 below.
YES
Power off the system, then go to step 2 below.
"Confirming the Initial Error Code" on page 131.
NO
Go to "SPCN Error Codes" on page 139 with the error codes you already have
and follow the instructions in the SPCN error code table.
YES
Go to "SPCN Error Codes" on page 139 with the error code(s) from step two
and follow the instructions in the SPCN error code table.
Chapter 5. Error Code to FRU Index
135