Service Processor Error Log - IBM 9114-275 - IntelliStation POWER 275 Service Manual

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

1. Remote session is already in progress.
2. Remote user uses service processor menus to enable console mirroring, allowing both consoles to
be active.
v Local session first, then remote session added:
1. Local session is already in progress.
2. The service processor receives a call from the remote user.
3. The local user selects the option to enable console mirroring. The service processor immediately
begins mirroring service processor menus.

Service Processor Error Log

The service processor error logs, an example of which follows, contain error conditions detected by the
service processor.
1. 11/30/99
19:41:56 Service Processor Firmware Failure
B1004999
Enter error number for more details.
Press Return to continue, or 'x' to return to menu.
Press "C" to clear error log, any other key to continue. >
Note: The time stamp in this error log is coordinated universal time (UTC), which is also referred to as
Greenwich mean time (GMT). Operating system error logs have additional information available and
can time stamp with local time.
Entering an error number provides nine words of system reference code (SRC) data; an example menu
follows.
Detail:
6005
SRC
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
word11:B1004999
word12:0110005D
word14:00000000
word15:00001111
word17:B1004AAA
word18:0114005D
B1004999
Press Return to continue, or 'x' to return to menu.
If Return is pressed, the contents of NVRAM will be dumped 320 bytes at a time, starting at address 0000.
224
IntelliStation POWER 9114 Model 275 Service Guide
Error Log
word13:00000000
word16:00000000
word19:A4F1E909

Advertisement