IBM 9114-275 - IntelliStation POWER 275 Service Manual page 80

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

No
Go to "Step 1321-14."
Yes
Go to "Step 1321-8."
Step 1321-8
From the list of open service action events with FRUs reported, examine the details of each service action
event and record the error code.
Step 1321-9
Examine the list of error codes you obtained from "Step 1321-8" and look for any of the form 4xxB xxxx,
A0D-34x, or A1D-34x.
Step 1321-10
Are there any error codes from "Step 1321-8" of the form 4xxB xxxx, A0D-34x, or A1D-34x?
No
Go to "Step 1321-13."
Yes
Go to "Step 1321-11."
Step 1321-11
Do any of the error codes from "Step 1321-8" of the form 4xxB xxxx, A0D-34x, or A1D-34x have the
same first two characters on the left as the first two characters on the left of the error code
recorded in "Step 1321-1" on page 61 that sent you to this MAP?
No
Go to "Step 1321-13."
Yes
Record the error codes from "Step 1321-8" of the form 4xxB xxxx, A0D-34x, or A1D-34x that have
the same first two characters on the left as the first two characters on the left of the error code
recorded in "Step 1321-1" on page 61 that sent you to this MAP. Also, record the service action
event associated with each error code. Go to "Step 1321-12."
Step 1321-12
From the list of open service action events with error codes of the form 4xxB xxxx, A0D-34x, or A1D-34x
recorded in "Step 1321-11," choose the service action event with the earliest time stamp (the one that
occurred first), record its error code and FRU location(s), and proceed to "Step 1321-14" with this new
code.
When future steps refer to the error code recorded in "Step 1321-1" on page 61, use this new error code
and its location code(s) instead of the original error code that sent you to this MAP.
Step 1321-13
From the list of open service action events with FRUs reported, choose the service action event with the
earliest time stamp (the one that occurred first), record its error code and FRU location(s), and proceed to
"Step 1321-14" with this new error code. When future steps refer to the error code recorded in "Step
1321-1" on page 61, use this new error code and its location code(s) instead of the original error code that
sent you to this MAP.
Step 1321-14
At the HMC console, open Service Focal Point (SFP) and examine the service action event log for any
closed service action events. For SFP operating instructions, refer to "Service Focal Point" on page 37.
Step 1321-15
Are there any service action events that are closed?
No
Go to the table in "Entry MAP" on page 41.
62
IntelliStation POWER 9114 Model 275 Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation power 9114 275

Table of Contents