Table 2. Firmware Checkpoints (continued)
Checkpoint
E5E7
E5E8
E5E9
E5EE
E5EF
E5FE
E600
E601
E602
E603
E604
E605
E60E
E60F
E6FF
E700
E701
124
IntelliStation POWER 9114 Model 275 Service Guide
Description
Save I/O hub information for RTAS and
open firmware
Set up registers
Reset the quick restart path
Hang state in main control code
End of low-level firmware
Get the system's licensed memory quantity
from the service processor
SSA PCI adapter open firmware has run
successfully.
SSA PCI adapter BIST has started but
failed to complete after 4 seconds.
SSA PCI open firmware has started.
SSA PCI adapter BIST has completed with
an error.
SSA PCI adapter BIST and subsequent
POSTs have completed successfully.
SSA PCI adapter BIST has completed
successfully but subsequent POSTS have
failed.
SSA PCI open firmware about to exit (no
stack corruption).
SSA PCI open firmware has run
unsuccessfully.
SSA PCI open firmware about to exit (with
stack corruption).
Create system firmware VPD
Create memory VPD.
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
1. Check for system firmware updates.
2. Go to "MAP 1540: Problem Isolation
Procedures" on page 87.
1. Replace the I/O drawer subsystem
backplane specified by the location
code.
2. Power down, then power up the
system.
3. Call service support.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
Replace the adapter.
System firmware may be corrupted.
Reinstall system firmware.
1. Check for system firmware updates.
2. Call for support.