Table 5. Firmware Error Codes. (continued)
Error Code Description
20E0 0009 Invalid password entered - system locked
20EE 0003 IP parameter requires 3 dots "."
20EE 0004 Invalid IP parameter
20EE 0005 Invalid IP parameter (>255)
20EE 0007 Keyboard not found
20EE 0008 No configurable adapters were found in the
system by the remote IPL menu in the SMS
utilities.
20EE 0009 Unable to communicate with the service
processor.
20EE 000A The image size on the boot or installation device 1. Check for system firmware updates. Apply if
20EE 000B The system was not able to find an operating
system boot record on the devices listed in the
boot list.
This can be caused by the wrong devices being
in the boot list, a problem that prevents the
system from communicating with the device that
contains the boot record, or the boot record
being corrupted.
148
IntelliStation POWER 9114 Model 275 Service Guide
Action/
Possible Failing FRU
The password has been entered incorrectly 3
times.
Turn off, then turn on the system unit, then enter
the password correctly.
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 255.192.002.000
1. Plug in keyboard.
2. Replace the system unit backplane.
Location: U0.1-P1
This warning occurs when the remote IPL menu
in the SMS utilities cannot locate any LAN
adapters that are supported by the remote IPL
function. If a supported device is installed:
1. Replace the adapter.
2. Go to "MAP 1542: I/O Problem Isolation" on
page 89.
1. Replace the service processor
Location: U0.1-P1-X1.
2. Replace the system unit backplane
Location: U0.1-P1.
available.
2.
Call service support.
Go to "Boot Problems/Concerns" on page 128.