IBM 9114-275 - IntelliStation POWER 275 Service Manual page 158

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

Table 4. SPCN Error Codes for the System Unit (continued)
Error Code Description
1011 2600
Pgood fault - power supply domain good
1011 2603
Pgood fault - power supply domain bad
1011 2612
Optical converter fault
1011 2630
1.2v VRM fault
1011 2631
1.5v VRM fault
1011 2632
1.8v VRM fault
1011 2633
2.5v VRM fault
1011 3100
I2C controller fault
1011 3104
I2C bus 4 fault
1011 3105
I2C interface fault
1011 3106
I2C interface fault
1011 3114
I2C interface fault
1011 3116
I2C interface fault
1011 3118
SPCN VPD collection fault
1011 3119
DASD backplane fault
1011 311A
DASD backplane fault
1011 311B
Media backplane fault
1011 7610
System fan 1 fault
1011 7611
System fan 1 missing
1011 7616
Power supply 2 fan missing
140
IntelliStation POWER 9114 Model 275 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation Procedures"
on page 87.
Go to "MAP 1540: Problem Isolation Procedures"
on page 87.
System backplane
Location: U0.1-P1
VRM module
Location: U0.1-P1-V3
System backplane
Location: U0.1-P1
VRM module
Location: U0.1-P1-V1
VRM module
Location: U0.1-P1-V2
System backplane
Location: U0.1-P1
DASD backplane
Location: U0.1-P2
DASD backplane
Location: U0.1-P3
Media backplane
Location: U0.1-P4
Service processor
Location: U0.1-P1-X1
System backplane
Location: U0.1-P1
System backplane
Location: U0.1-P1
System backplane
Location: U0.1-P1
System backplane
Location: U0.1-P1
System backplane
Location: U0.1-P1
System backplane
Location: U0.1-P1
DASD backplane
Location: U0.1-P2
DASD backplane
Location: U0.1-P3
Media backplane
Location: U0.1-P4
Fan 1
Location: U0.1-F1
Fan 1
Location: U0.1-F1
System drawer power supply 2
Location: U0.1-V2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation power 9114 275

Table of Contents