IBM 9114-275 - IntelliStation POWER 275 Service Manual page 179

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

Table 5. Firmware Error Codes. (continued)
Error Code Description
2B20 8884 Unrecoverable processor subsystem error
2B20 8885 Unrecoverable internal hardware error
2B20 8888 Operating system termination request received
2B2x 00EE Description: An exception error has been reported on a global processor
Action: The type of interrupt that caused the exception is specified by the x as follows:
0:
1:
2.
3.
4.
5.
6.
7.
8.
1. Check for system firmware updates. Apply if available.
2. Call service support.
2BA0 0000 Service processor POST failure
2BA0 0012 Service processor reports self test failure
2BA0 0013 Service processor reports bad NVRAM CRC
2BA0 0017 Service processor reports bad or low battery.
2BA0 0021 Open firmware mailbox call to activate attention
LED failed
2BA0 0041 Service processor VPD is corrupted.
Unknown interrupt
System reset interrupt (SRI)
Machine check interrupt (MCI)
Data storage interrupt (DSI)
Instruction storage interrupt (ISI)
External interrupt (EXI)
Alignment interrupt (ALI)
Program interrupt (SRI)
Floating unavailable interrupt (FUI)
Action/
Possible Failing FRU
If Linux is the only operating system on the
failing system, call service support.
If AIX is available, and the system is powered
down, replace the FRU indicated by the service
processor error log entry. If AIX is available and
the system has been rebooted, run online AIX
diagnostics and look for an AIX error log entry in
which the description says cache or cache
controller error. Replace the FRUs listed with
this entry.
If Linux is the only operating system on the
failing system, call service support.
If AIX is available, run online AIX diagnostics
and look for an AIX error log entry in which the
description says I/O bus time-out, access, or
other error, or I/O bridge/device internal error.
Replace the FRUs listed with this entry.
Informational message.
Replace service processor
Location: U0.1-P1-X1
Replace service processor
Location: U0.1-P1-X1
Refer to the actions for error code 25A8 0xxx.
1. Replace the battery, U0.1-P1-X1-V3.
2. Refer to the actions for error code 25A8
0xxx.
Call service support.
Replace system backplane
Location: U0.1-P1-X1
Chapter 5. Error Code to FRU Index