Map 1020: Problem Determination - IBM 9114-275 - IntelliStation POWER 275 Service Manual

Service guide
Hide thumbs Also See for 9114-275 - IntelliStation POWER 275:
Table of Contents

Advertisement

MAP 1020: Problem Determination

Purpose of This MAP
Use this MAP to get an error code if you were not provided one by the customer or you are unable to load
diagnostics. If you are able to load the diagnostics, go to MAP 0020 in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
The service processor may have recorded one or more symptoms in its error log. Examine this error log
before proceeding (see "System Information Menu" on page 205).
The service processor may have been set by the user to monitor system operations and to attempt
recoveries. You can disable these actions while you diagnose and service the system. If the system was
set up according to the recommendations of the IntelliStation POWER 9114 Model 275 User's Guide, all
the settings of the service processor (except language) were saved by using the SAVE/RESTORE
HARDWARE MAINTENANCE POLICIES service aid. You can use the same service aid to restore the
settings at the conclusion of your service action.
In case the service processor settings were not saved by the user, if you disable them, make notes of their
current settings for restoration before you leave.
In addition to the parameters in the following table, you can disconnect the modem to prevent incoming
signals that could cause the system to power on.
Following are the service processor settings. The service processor menus are described in Chapter 7,
"Using the Service Processor," on page 193.
Surveillance
Unattended Start
Reboot Policy
Call-Out
From the service processor Setup Menu, go to the
Surveillance Setup Menu and disable surveillance.
From the service processor System Power Control Menu,
disable unattended start mode.
From the System Power Control Menu, go to the
Reboot/Restart Policy Setup Menu and set:
1. Number of reboot attempts to 0 (zero)
2. Use OS-Defined restart policy to No
3. Enable supplemental restart policy to No.
From the Call-In/Call-Out Setup Menu, go to the Serial
Port Selection Menu and disable call-out on both serial
ports.
Chapter 3. Maintenance Analysis Procedures (MAPs)