SPCN Error Codes

Attention:
If a power supply or fan is hot-swapped, wait five minutes, then recheck the operating system
error log. If the system has to be shut down to replace a power supply or fan, reboot the system, wait five
minutes after the operating system login prompt appears, then recheck the operating system error log. If
the detailed information for the most recent error with the same identifier indicates that the original problem
has not been fixed by performing the first action in the action column, continue with the next action in the
action column.
Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to "MAP
1540: Problem Isolation Procedures" on page 87 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the RS/6000
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Table 4. SPCN Error Codes for the System Unit
Error Code Description
1011 00AC
AC loss
1011 00EF
Emergency power off
1011 1510
Power supply 1 AC fault
1011 1511
Power supply 1 power fault
1011 1512
Power supply 1 non-power fault
1011 1513
Domain fault allocated to power supply 1
1011 1514
Power supply 1 fan fault
1011 1520
Power supply 2 AC fault
1011 1521
Power supply 2 power fault
1011 1522
Power supply 2 non-power fault
1011 1523
Domain fault allocated to power supply 2
1011 1524
Power supply 2 fan fault
1011 1B0A
+12/-12V load fault
1011 1B0B
1.8V load fault
1011 1B0C
3.3/1.5V load fault
1011 1B0D
2.5V load fault
1011 1B0E
+5V load fault
1011 1B0F
1.5/1.2V load fault
1011 1F01
TMS limit reached - Log Only
Action/
Possible Failing FRU
Informational message
Informational message
1. Check input power to the power supply.
2. System drawer power supply 1
Location: U0.1-V1
System drawer power supply 1
Location: U0.1-V1
System drawer power supply 1
Location: U0.1-V1
System drawer power supply 1
Location: U0.1-V1
System drawer power supply 1
Location: U0.1-V1
1. Check input power to the power supply.
2. System drawer power supply 2
Location: U0.1-V2
System drawer power supply 2
Location: U0.1-V2
System drawer power supply 2
Location: U0.1-V2
System drawer power supply 2
Location: U0.1-V2
System drawer power supply 2
Location: U0.1-V2
Go to "MAP 1520: Power" on page 76.
Go to "MAP 1520: Power" on page 76.
Go to "MAP 1520: Power" on page 76.
Go to "MAP 1520: Power" on page 76.
Go to "MAP 1520: Power" on page 76.
Go to "MAP 1520: Power" on page 76.
Informational message
Chapter 5. Error Code to FRU Index
139