Table 9. Common Firmware Error Codes (continued)
Error Code Description
B10F 1381 Service processor flash error
B10F 1384 Service processor failure
B10F 1387 Service processor failure
B10F 1400 Service processor failure
B10F 1401 Service processor failure
B10F 1670 Service processor flash update failure
B10F 1672 Service processor firmware update invalid
B10F 1675 Service processor failure
B10F 1681 Service processor firmware update invalid
B10F 1682 Service processor firmware update invalid
B10F 1683 Service processor firmware update invalid
B1xx 0013 An attempt was made to flash (update) the
firmware from AIX using the wrong image for this
system. No flashing took place; the firmware
level was not changed.
B1xx 4600 Service processor failure
B1xx 4601 System processor failure
Action/
Possible Failing FRU
1. Update system firmware
2. Service processor
Location: U0.1-P1-X1
Service processor
Location: U0.1-P1-X1
Service processor
Location: U0.1-P1-X1
Service processor
Location: U0.1-P1-X1
Service processor
Location: U0.1-P1-X1
1. Retry flash update
2. Service processor
Location: U0.1-P1-X1
Call service support
Service processor
Location: U0.1-P1-X1
Call service support
Call service support
Call service support
Retry the firmware update from AIX using the
correct flash image.
Service processor
Location: U0.1-P1-X1
Go to "MAP 1540: Problem Isolation Procedures"
on page 87.