Table 5. Firmware Error Codes. (continued)
Error Code Description
21EE 0001 Undetermined SCSI device type - test unit ready
failed - hardware error
21EE 0002 Undetermined SCSI device type - test unit ready
failed - sense data available
21EE 0003 Undetermined SCSI device type - send
diagnostic failed - sense data available
21EE 0004 Undetermined SCSI device type - send
diagnostic failed - DevOfl cmd
21F0 0001 SCSI DVD-RAM - test unit ready failed -
hardware error
21F0 0002 SCSI DVD-ROM - test unit ready failed - sense
data available
21F0 0003 SCSI DVD-RAM - send diagnostic failed - sense
data available
21F0 0004 SCSI DVD-RAM - send diagnostic failed -
DevOfl cmd
21F2 0001 SCSI read/write optical - test unit ready failed -
hardware error
21F2 0002 SCSI read/write optical - test unit ready failed -
sense data available
Action/
Possible Failing FRU
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. If the missing SCSI devices are connected to
the same backplane, replace the SCSI
backplane.
4. Replace the SCSI controller.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the media (removable media
devices).
2. Replace the SCSI device.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
Replace the SCSI device.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
Replace the SCSI device.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the media.
2. Replace the SCSI device.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
Replace the SCSI device.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
Replace the SCSI device.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
Before replacing any system components, refer
to the notes in error code 21A0 0001.
1. Replace the media.
2. Replace the SCSI device.
Chapter 5. Error Code to FRU Index