Table 5. Firmware Error Codes. (continued)
Error Code Description
2803 F003 Real-time-clock not updating - not correctable
(detected by hypervisor)
2900 0002 Keyboard/mouse controller failed self-test
29A0 0003 Keyboard not present/detected
29A0 0004 Keyboard stuck key detected
29B0 0004 Mouse not present/detected
2B20 0011 Processor is manually disabled
2B20 0012 This is an informational code that is generated
when the AIX cpu_deallocatecommand is used
to take a processor off-line.
2B20 0022 Processor is deconfigured by the system
2B20 0031 Processor is failing POST.
2B20 0042 Unknown processor card
2B20 8880 Unrecoverable internal hardware error
2B20 8881 Software error
2B20 8882 Software error
2B20 8883 Software error
160
IntelliStation POWER 9114 Model 275 Service Guide
Action/
Possible Failing FRU
Replace the service processor
Location: U0.1-P1-X1
Replace service processor
Location: U0.1-P1-X1
1. Keyboard
2. Replace service processor
Location: U0.1-P1-X1
1. Keyboard
2. Replace service processor
Location: U0.1-P1-X1
1. Mouse
2. Replace service processor
Location: U0.1-P1-X1
Use the service processor menus to re-enable
the processor and reboot the system
There is no action required.
To bring the processor back on-line (back into
the system's or partition's configuration), reboot
the operating system.
The processor has previously failed BIST or
POST. Replace the processor card indicated by
the location code associated with the error code
in the error log.
Replace the processor card indicated by the
location code associated with the error code in
the error log.
Remove the unknown/unsupported system unit
backplane.
If Linux is the only operating system on the
failing system, call service support.
If AIX is available, and the system is powered
down, replace the FRU indicated by the service
processor error log entry. If AIX is available and
the system has been rebooted, run online AIX
diagnostics and look for an AIX error log entry in
which the description says cache or cache
controller error. Replace the FRUs listed with
this entry.
Call service support.
Call service support.
Call service support.