Operator Panel Error Codes

Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to "MAP
1540: Problem Isolation Procedures" on page 87 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the RS/6000
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Table 3. Operator Panel Error Codes.
Error Code Description
0000 1111 At power on, failure of power-good signal from
power supply.
0000 1112 At power off, failure of power-good signal from
power supply.
0000 1113 While power on, failure of power-good signal
from power supply.
0000 1114 Operator panel and service processor have been
reset after main power disturbance.
0000 2222 Operator panel not communicating with service
processor
0000 3333 SPCN communications error
0000 3334 I2C repeater error
0000 BBBB TOD battery malfunction
138
IntelliStation POWER 9114 Model 275 Service Guide
Action/
Possible Failing FRU
1. System unit backplane
Location: U0.1-P1
2. System unit backplane power supply
Locations:
U0.1-V1
U0.1-V2
1. System unit backplane
Location: U0.1-P1
2. System unit backplane power supply
Locations:
U0.1-V1
U0.1-V2
1. System unit backplane
Location: U0.1-P1
2. System unit backplane power supply
Locations:
U0.1-V1
U0.1-V2
Informational message
1. If system cannot be powered off, reset the
service processor (via the pinhole reset or by
disconnecting then reconnecting power).
2. System unit backplane
Location: U0.1-P1
System unit backplane
Location: U0.1-P1
System unit backplane
Location: UO.1-P1
TOD battery
Location: U0.1-P1-V3