Table 6. Service Processor Error Codes. (continued)
Error Code Description
406x 0EBF Memory error
406x 0EE1 Service processor firmware: invalid MRU to FRU
mapping
406x 0EE2 Service processor firmware fault
406x 0EE5 Firmware error, no callout available
4503 26F5 Description: System backplane with 2 processors fault:
Action: This error code indicates that the processor repeat gard function has deconfigured a
processor. Do the following:
1. Go to the processor configuration/deconfiguration menu, located under the system information
menu in the service processor menus.
Look at the status of the processors. If any of the processors have a status of manually
deconfigured, reconfigure the processor(s) and boot the system to the SMS menus. Power off
the system using the white power button and look again at the status of the processors. If all of
the processors are still configured in the processor configuration/deconfiguration menu, the
problem has been resolved.
If any of the processors have a status of deconfigured by the system, either before or after the
boot to the SMS menus, go to step 2.
2. Replace the processor card (on which the deconfigured processor resides) specified by the
location code.
166
IntelliStation POWER 9114 Model 275 Service Guide
Action/
Possible Failing FRU
1. Reboot the system in slow mode to the SMS
menus. See "Performing a Slow Boot" on
page 131.
2.
Examine the service processor error log.
a.
If a system unit subsystem error (a 4xxx
yyyy error) occurred during the slow boot
calling out the memory, processors, L3
cache modules or the primary I/O book,
replace the part indicated by the location
code.
b.
If a system unit subsystem error (a 4xxx
yyyy error) did not occur during the slow
boot, look for a 4xxx yyyy error
immediately preceding the 406x 0EBF
error. Replace the part indicated by the
location code associated with that error.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.