Step 1322-9
Is the FRU list identical (same FRUs, same number of FRUs, and same order of FRUs) to the FRU
list of the error code recorded in "Step 1322-1" on page 71?
No
Go to "Step 1322-10."
Yes
Go to "Step 1322-11."
Step 1322-10
The FRU list is different.
Is the FRU you replaced and recorded in "Step 1322-1" on page 71 in the list of FRUs for this
service action event?
No
Go to "Step 1322-33" on page 74.
Note: There are service action events that will remain open when you leave this MAP. Further
service actions may be required to complete the repair.
Yes
Go to "Step 1322-11."
Step 1322-11
Examine the details of this service action event, and record the partition(s) involved in this service action
event for use in a later step.
Step 1322-12
Is the error code associated with this service action event of the form A11-xxx or A01-xxx?
No
Go to "Step 1322-17" on page 73.
Yes
Go to "Step 1322-13."
Step 1322-13
Have you begun a list of "Axx" partitions from prior service action events that you processed in
this MAP?
No
Go to "Step 1322-14."
Yes
Go to "Step 1322-15."
Step 1322-14
Begin a new list of "Axx" partitions by copying the list of partitions obtained in "Step 1322-11." Go to "Step
1322-16" on page 73.
Step 1322-15
Add the partition list obtained in "Step 1322-11" to the existing list of "Axx" partitions obtained from
processing previous service action events in this MAP.