Replacing The Power Supply Distribution Module (Dc Version) - Intel SR2400SYS - Server Platform - 0 MB RAM User Manual

Server chassis
Table of Contents

Advertisement

Hardware Installations and Upgrades
21. Install the processor air duct. For instructions, see
22. Install the chassis cover. For instructions, see
Replacing the Power Supply Distribution Module (DC
Version)
NOTE
This procedure only applies to the DC version of the Intel® Server Chassis SR2400. If you are
replacing a power distribution module for the AC version of the Intel® Server Chassis SR2400, see
"Replacing the Power Supply Distribution Module (AC Version)" for instructions.
The power supply distribution module is at the front of the power supply. This module can be
replaced if it fails. To replace the power supply distribution module, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See
Information."
2. Power down the server and unplug all peripheral devices and the DC power source.
3. Remove the chassis cover. For instructions, see
4. Remove the air baffle. If you are using fixed drives, see
(No Backplane
Large Hot-swap Air Baffle (Backplane
5. Remove the hot swap power supply/supplies. For instructions, see
Power
Supply."
6. Remove the PCI riser assembly. For instructions, see
Intel® Server Chassis SR2400/SR2400DC User Guide
Installed)" for instructions. If you are using hot-swap drives, see
Installed)" for instructions.
"Installing the Processor Air
"Installing the Chassis Cover."
"Removing the Chassis Cover."
"Removing the Fixed Drive Air Baffle
"Removing a Hot-swap
"Removing the PCI Riser
Duct."
"Safety
"Removing the
Assembly."