Replacing the Power Supply Distribution Module (AC
Version)
NOTE
This procedure only applies to the AC version of the Intel® Server Chassis SR2400. If you are
replacing a power distribution module for the Intel® Server Chassis SR2400DC, see "Replacing
the Power Supply Distribution Module (DC Version)" for instructions.
The power supply distribution module is at the front of the power supply. This module can be
replaced if it fails. To replace the power supply distribution module, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See
Information."
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see
4. Remove the air baffle. If you are using fixed drives, see
(No Backplane
Large Hot-swap Air Baffle (Backplane
5. Remove the hot swap power supply/supplies. For instructions, see
Power
Supply."
6. Remove the PCI riser assembly. For instructions, see
72
Installed)" for instructions. If you are using hot-swap drives, see
Installed)" for instructions.
"Removing the Chassis Cover."
"Removing the Fixed Drive Air Baffle
"Removing a Hot-swap
"Removing the PCI Riser
"Safety
"Removing the
Assembly."