Hardware Installations and Upgrades
Installing or Replacing a Hot-swap Power Supply (AC
Version)
The power supply can be replaced if it, or one of the fans integrated into it, fails. If your server uses
a redundant power supply, you do not need to power down your server to replace the failed power
supply, as long as the remaining power supply is plugged into an AC power source and is
functioning. If you do not have a redundant power supply installed, you must power down your
server system before replacing the power supply.
✏
NOTE
This procedure only applies to the AC version of the Intel® Server Chassis SR2400. If you are
installing or replacing a hot swap power supply for the Intel® Server Chassis SR2400DC, see
"Installing or Replacing a Hot-swap Power Supply (DC Version)" for instructions.
Removing a Hot-swap Power Supply
To replace the power supply, use the following instructions.
1. (Non-redundant power supply only) Power down the server.
2. Remove the AC power cable from the failed power supply.
3. Press the green latch at the rear of power supply and pull the power supply from the chassis.
Intel® Server Chassis SR2400/SR2400DC User Guide
Figure 75. Removing a Hot-swap Power Supply
TP01119