Figure 21. Installing Hard Disk Drive – Removing plastic drive blank
3. Install the hard disk drive using the four screws as shown. Make sure the connector end of the
drive matches the backplane connector (see letter "E").
4. With the lever open, insert the hard disk drive assembly into the chassis, then push in the lever
to lock it into place (see letter "F").
Figure 23. Installing Hard Disk Drive – Inserting 2.5" HDD assembly

Replacing the Power Supply

Caution: The power supply is only hot-swappable if you have a redundant system with two power
supplies installed. If you only have one power supply installed, before removing or replacing the
power supply, you must first take the system out of service, turn off all peripheral devices connected
to the system, turn off the system by pressing the power button, and unplug the power cord from the
system or wall outlet.
The power supply can be replaced if it fails. To replace the power supply, follow these steps:
1. Do one of the following:
If a filler panel is installed, use the 'finger hole' to remove the filler panel (see letter "A").
-
®
Intel
JBOD2000 Family Service Guide
Figure 22. Installing Hard Disk Drive – Installing 2.5" HDD
Hardware Installations and Upgrades
19