Field Replaceable Units (FRUs)
FRU Removal and Replacement

DC/DC Converter Units and Air Dividers (J7000 Only)

The J7000 workstation has two DC/DC converter units and two air dividers on its left side.
(The J5000 does not require any DC/DC converter units nor the air dividers.) The DC/DC
converter units and air dividers are attached to the J7000 by metal tie-down straps. Each
DC/DC converter unit connects to the system board by a 30-pin connector.
Removing the DC/DC Converter Units and Air Dividers
To remove the DC/DC converter units and air dividers, do the following:
1. Remove the J7000 workstation's top panel and left side panel.
2. On the left side of the workstation, remove the four T-15 Torx screws from the front air
divider as shown in Figure 4-18, and then remove the front air divider.

Figure 4-18. Screws on the Front Air Divider

3. There are two tie-down straps over the DC/DC converter units and the rear air divider,
as shown in Figure 4-19 on the next page. The front edge of each metal tie-down slips
into a slot on the system board fan wall, and the rear edge is secured by a T-15 Torx
screw on the rear panel of the workstation. Each metal tie-down is also secured to the
rear air divider by a T-15 Torx screw.