Battery on I/O Board
The battery in the J5000 and J7000 workstations is contained within the real-time clock
module on the I/O board. This section describes how to remove and replace the real-time
clock module containing the battery.
Removing the Battery on the I/O Board
To remove the battery from the I/O board, do the following:
1. Remove the top panel and the right side panel of the workstation.
2. Locate the I/O board and its I/O slots on the right side of the workstation, as shown in
Figure 4-37. Note that the I/O board extends up behind the power supply, and that the
eight I/O slots are located below the power supply.
Figure 4-37. I/O Board
PCI retainer clip
3. Remove the PCI retainer clip by pressing down on the thumb tab and pulling the clip
forward to rotate it out of the chassis floor hole, as shown in Figure 4-38 on the next
page.
Chapter 4
Field Replaceable Units (FRUs)
FRU Removal and Replacement
Power supply
I/O board (extends
up behind the power
supply, above)
125
Need help?
Do you have a question about the Visualize J7000 and is the answer not in the manual?
Questions and answers