RS-422 Connector
A 15-way, D-type female connector
provides an RS-422 synchronous, serial
communications data input interface.
Table 2.11: RS-422 Data Connector (Base Board) - Synchronous
Remote (DTE)
Signal Name
Transmit Data A
Transmit Clock A
Signal Ground
Transmit Data B
Transmit Clock B
NOTE...
Signal names are with respect to a DTE in accordance with the RS-422 specification. A is positive and
B is negative.
2.6

Powering Up/Down

2.6.1

Before Powering Up

Before powering up the Encoder, check that:
1. The unit has been installed in a suitable location.
2. The unit has been connected to external equipment and power supply,
as required.
3. The power supply has been checked and a good earth provided.
4. The correct fuse type and rating has been fitted to the equipment and,
for the ac supply version, the ac power cable.
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1
Encoder RS-422 (DCE)
Signal Direction
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Signal Name
Not connected
Transmit Data A
Not connected
Not connected
Not connected
Not connected
Transmit Clock A
Signal Ground
Transmit Data B
Not connected
Not connected
Not connected
Not connected
Transmit Clock B
Not connected
Installing the Equipment