Technical Specification
B.7
Environmental Conditions
Table B.19: Environmental Specification
Item
Operational
Temperature
Over temperature alarm
generated at
Under temperature alarm
generated at
Temperature checked
All fans switched off at
Half the fans switched off at
All fans on at
Relative humidity
Cooling requirements
Handling/movement
Storage/Transportation
Temperature
Relative humidity
B.8
Compliance
B.8.1
Safety
This equipment has been designed and tested to meet the requirements of
the following:
EN 60950
IEC 60950
In addition, the equipment has been designed to meet the following:
UL 1950
1
The version of the standards shown is that applicable at the time of manufacture.
Page B-12
Specification
-10°C to +50°C (14°F to 122°F) ambient with free air-flow
>= 55°C
< 0°C
Once every 30 seconds
< 10°C (when set to auto)
< 20°C (when set to auto)
>= 20°C (when set to auto)
0% to 90% (non-condensing)
Front section: Cool air input from front panel, exhaust from right side of unit
Rear section: Cool air input from right side of unit, exhaust from left side of unit
See Chapter 2, Installing the Equipment, Figure 2.2
Designed for stationary or fixed use when in operation
0°C to +70°C (32°F to 158°F)
0% to 90% (non-condensing)
1
European
Safety of information technology equipment
including business equipment.
International
Safety of information technology equipment
including business equipment.
USA
Safety of information technology equipment
including business equipment.
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1