Preventive Maintenance and Fault-finding
Investigate any run-time errors by pressing the Active Errors softkey in
the Errors Menu (see Figure 6.1). Current errors are displayed.
Refer to Chapter 4, Operating the Equipment Locally, Figure 4.19 for
further details of error messages.
It does not mean that the Encoder is fully functional if the Error option does not produce any results.
NOTE...
This function can be used with the Encoder still in service.
6.4.2
Diagnostics Menu
Introduction
The Diagnostics Menu is selected from the Advanced Menu by pressing
the Diagnostics softkey. This menu has a selection of diagnostic tests
which allow the operator to test the individual component parts of the
equipment.
Summary Screen
Ops ...
Cfgs
More ...
Quit
Figure 6.2: Finding the Diagnostics Menu
LCD Display Test
Press the LCD Display softkey to access the option and then press any
key to cycle through the test patterns and to return to the menu.
Keyboard Test
Press the Keyboard softkey to access the option and then press each
softkey and keypad key in turn. The display shows the name of each key
pressed. Press the Quit softkey to return to the menu.
Page 6-6
CAUTION...
Some processes cannot be tested on-line.
Advanced Menu
Setup ...
Errors...
Diagnostics...
Ops ...
Front Panel Diagnostics Menu
Configs
Quit
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
LCD Display
Keyboard
Fail Relay
Alarm Relay
Alarm LED
Buzzer
Quit
Errors Menu
Active Errors
Error Masks
Quit
ST.TM.E10074.1