Video Fault-Finding; Fault Symptoms - TANDBERG evolution 5000 E5710 Instruction Manual

Table of Contents

Advertisement

To replace the ac power fuse:
BEFORE REPLACING THE REAR PANEL FUSE, DISCONNECT THE UNIT FROM THE SUPPLY.
FAILURE TO DO THIS MAY EXPOSE HAZARDOUS VOLTAGES. UNPLUG THE UNIT FROM THE
1. Ensure that power is turned off and the power cable is disconnected
from the ac power inlet.
2. Ease out the fuse carrier by placing a small, flat-bladed screwdriver in
the notch at the top of the carrier.
When replacing the power input fuse, always ensure that a fuse of the correct type and rating, is fitted.
3. Replace the fuse in the carrier.
4. Insert the fuse carrier back in the ac power inlet.
AC Power Inlet
Figure 6.3: Orientation of Fuse Carrier
If the replacement fuse also blows, do not continue. Disconnect the
equipment and contact Customer Services for advice.
6.5.4

Video Fault-finding

Fault Symptoms

Table 6.2: Video Fault-finding
Problem
Video input lock error
Video - wrong line standard
VCM stopped
Bad parameters
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1
WARNING...
LOCAL SUPPLY SOCKET.
CAUTION...
Failure to do so results in inadequate protection.
What to do
Check video input.
Check which video format is selected.
Reboot.
Check set-up.
Preventive Maintenance and Fault-finding
If required, use a small flat-bladed
screwdriver in the notch at the top
of the carrier to ease it out.
Fuse Carrier