B.3
ASI Out 1, ASI Out 2, ASI Out 3 Outputs
Table B.12: ASI Out Specification
Item
Safety status
Connector type
Connector designation
B.4
Control and Monitoring
B.4.1
Remote Control - Ethernet 1 and 2
Table B.13: Ethernet Specification
Item
Safety status
Connector designation
Connector type
B.4.2
Local Control
Local control is by means of the front panel keypad and LCD display.
B.4.3
Alarm
Table B.14: Alarm Specification
Item
Safety status
Connector designation
Connector type
Alarm contacts
Fail contacts
Reset contacts
Relay Contact Rating
Maximum switching power
Maximum switching voltage
Maximum switching current
B.4.4
Remote Control
This connector provides an RS-232/RS-485 user interface control port that
allows the unit to be controlled by an external master.
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1
Specification
SELV
BNC 75 W
ASI OUT 1, ASI OUT 2, ASI OUT 3
Specification
SELV
ETHERNET#1 and ETHERNET#2
8-way RJ-45 socket, 10BaseT (ISO 882/3)
Specification
SELV
ALARM
9-way D-type male
Change-over contacts (5 W in common)
Change-over contacts (5 W in common)
Short pins 9 and 5 (resets the Encoder)
30 W
110 V
1 A
Technical Specification
Page B-9