Alarm

If required, connect an external status monitoring
device to the ALARM connector.
A 9-way, D-type male connector provides an alarm
relay interface which can be used to send a signal to
remote equipment.
Table 2.8: Alarm Connector
Pin
1
2
3
4
5
Fail
Common
Alarm
Common
NOTE...
NC = Normally Closed, NO = Normally Open, and refers to the relay contacts. Refer to Annex B,
Section B.4.3, Alarm for details of the relay contact rating.

Remote Control

A 9-way, D-type male connector provides an
RS-232/RS-485 port for remote control of the
Encoder (see Serial Protocol Option on
page 4-23). This connector is wired as a DTE.
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1
Signal
Pin
Ground
6
Fail (common)
7
Alarm (NO)
8
Alarm (+) (NC)
9
Reset 1 (internally pulled
to 3.3 V via 10 kW)
Fail (NC)
Fail (NO)
Alarm (NC)
Alarm (NO)
Signal
Fail (NO)
Fail (NC)
Alarm (common)
Reset 2 (internally grounded)
3.3 V
10 kW
Reset 1
Reset 2
Installing the Equipment
Page 2-13