Installing the Equipment
The unit is designed for stationary or fixed use only. Ensure it is firmly and
safely located and has an adequate through-flow of air. Allow at least
50 mm free air-space at each side of the equipment. Units in racks can be
stacked without ventilation panels between. Racks containing stacked
equipment may need to be forced-air cooled to reduce the operating
ambient temperature. For stacking constraints contact Customer Services.
The 1U Encoder uses a similar air-flow path, with three fans on each side
of the unit. With both 1U and 2U units it is important not to block the front
air intake on the bottom-left corner of the front panel (see Figure 2.2).
Three fans mounted
at rear, left side of
unit
4
Warm air out
(left, rear)
Figure 2.2: Air Path through the Enclosure
2.4

AC Mains Operating Voltage and Earthing

2.4.1

AC Power Supply

This product should be operated only from the type of power source indicated on the marking label. If
you are not sure of the type of power supply to your business, consult a qualified electrical engineer or
See Annex B, Technical Specification for a full power supply specification.
There are no links or switches to be altered for operation from different ac
supplies.
Page 2-6
3
Cool air in
(right, rear)
1
Cool air in
(front – via bottom vent)
Do not block the air intake.
CAUTION...
your local power company.
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
2
Warm air out
(right, front)
Two fans mounted
at front, right side
of unit
ST.TM.E10074.1