4.12.4 Bit-Rate (188) And Bit-Rate (204) Option; 4.12.5 Clock; 4.12.6 Pcr Pid Option - TANDBERG evolution 5000 E5710 Instruction Manual

Table of Contents

Advertisement

Table 4.83: On Air Options
Selected Option
On
Off

4.12.4 Bit-rate (188) and Bit-rate (204) Option

NOTE...
If the Packet Length option is set to 188 bytes then only the Bit-rate (188) option is displayed. If the
Packet Length option is set to 204 bytes then both the Bit-rate (188) and Bit-rate (204) options are
displayed.
To access the either of the bit-rates, press the Bit-rate (188) or the
Bit-rate (204) softkey in the Mux Menu.
Both the Bit-rate (188) and the Bit-rate (204) can be in the range of
0 Mbit/s to 50 Mbit/s.
Bit-rate (188)
Can also be 204
¬ Left
® Right
l Ins
l Del
Table 4.84: Bit-rate (188) and Bit-rate (204) Options
Selected Option
188 / 204
Min:
Max:
Step Size: 0.0001 Mbit/s
If the specified bit-rate is outside the valid input range, a confirmation
screen is displayed which shows the maximum/minimum value allowed.

4.12.5 Clock

This option indicates the origin of the clock. It is set to Local Oscillator, is
for status only and cannot be changed.

4.12.6 PCR PID Option

To access the PCR PID option, press the PCR PID softkey in the Mux Menu.
This shows the Program Clock Reference Packet Identifier.
PCR PID
¬ Left
® Right
l Ins
l Del
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1
Description
Multiplexer output is switched on.
Multiplexer output is switched off.
Bit-rate (188) :
`40.000 Mbit/s'
Update using softkeys
Description
Multiplexer output bit-rate when in baseband output format
0.0000 Mbit/s
and ASI output mode.
50.0000 Mbit/s
Changing the bit-rate affects the automatic video bit-rate
and video resolution calculations.
PCR PID :
`32 (0020h)'
Update using softkeys
Operating the Equipment Locally
+
Enter l
Quit l
+
Enter l
Quit l
Page 4-83