Rack Warnings And Cautions - HPE ProLiant DL365 Gen11 Maintenance And Service Manual

Table of Contents

Advertisement

WARNING:
WARNING:
To reduce the risk of fire or burns after removing the energy pack:
Do not disassemble, crush, or puncture the energy pack.
Do not short external contacts.
Do not dispose of the energy pack in fire or water.
Do not expose the energy pack to low air pressure as it might lead to explosion or leakage of flammable liquid or gas.
Do not expose the energy pack to temperatures higher than 60°C (140°F).
After power is disconnected, battery voltage might still be present for 1s to 160s.
CAUTION:
CAUTION:
Protect the from power fluctuations and temporary interruptions with a regulating UPS. This device protects the
hardware from damage caused by power surges and voltage spikes and keeps the in operation during a power failure.
CAUTION:
CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or
replacement procedure. Improper grounding can cause electrostatic discharge.
CAUTION:
CAUTION:
To avoid data loss, Hewlett Packard Enterprise recommends that you back up all server data before installing or removing
a hardware option, or performing a server maintenance or troubleshooting procedure.
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this
CAUTION:
manner results in improper airflow and improper cooling that can lead to thermal damage.

Rack warnings and cautions

Rack warnings and cautions
WARNING:
WARNING:
When all components are removed, the server weighs ( ). When all components are installed, the server can weigh up to
( ).
Before configuring your rack solution, be sure to check the rack manufacturer weight limits and specifications. Failure to do
so can result in physical injury or damage to the equipment and the facility.
WARNING:
WARNING:
The server is heavy. To reduce the risk of personal injury or damage to the equipment, do the following:
Observe local occupational health and safety requirements and guidelines for manual material handling.
Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to
the rails. The server weighs more than ( ), so at least two people must lift the server into the enclosure together. An
additional person may be required to help align the server if the server is installed higher than chest level.
Use caution when installing the server in or removing the server from the enclosure.
Adequately stabilized the enclosure before extending a component outside the enclosure. Extend only one component
at a time. A enclosure may become unstable if more than one component is extended.
Do not stack anything on top of rail-mounted component or use it as a work surface when extended from the rack.
HPE ProLiant DL365 Gen11 Server Maintenance and Service Guide