4-12
Wiring 1394 GMC and GMC Turbo Systems
SW1
Port J1, J2
Left
No DH-485 Terminal
Right
DH-485 Terminal (220Ω)
Publication 1394-5.0 — May 2000
Figure 4.10
SW1 - SW6 (RS-232/RS-422) Switch Settings
SW2
SW3
Port J4
Port J3
No RS-422 Terminal
No RS-422 Terminal
RS-422 Terminal (220Ω)
RS-422 Terminal (220Ω)
When a port is configured for RS-232 operation, you can connect
compatible serial communication devices using common RS-232
cables. Refer to the table below for signal designations and Figure
4.11 for cable recommendations. Refer to the IMC S Class Motion
Control Installation and Setup Manual (publication 999-122) for
multidrop application instructions.
RS-232
Pin
Signal
Description
1
NC
No Connection
2
TxD
Transmitted Data
3
RxD
Received Data
4
DTR
Data Terminal Ready
5
Com
Signal Common
6
DSR
Data Set Ready
7
RTS
Ready To sent
8
CTS
Clear To Send
9
NC
No Connection
Refer to Data Highway Connection for DH-485 signal designations.
Important: The RTS/CTS and DSR/DTR signals are internally
jumpered to allow you to use standard RS-232 cables
with serial devices requiring hardware handshaking.
SW4
SW5
Port J1, J2/J4
Port J4
RS-232/422
RS-232
DH-485
RS-422
RS-422
Pin
Signal
Description
1
TxD+
Transmitted Data (+)
2
TxD-
Transmitted Data (-)
3
RxD-
Received Data (-)
4
TxD+
Transmitted Data (+)
5
Com
Signal Common
6
TxD+
Transmitted Data (+)
7
RxD+
Received Data (+)
8
RxD+
Received Data (+)
9
NC
No Connection
SW6
Port J3
RS-232
RS-422