The AM50/75 are designed to mount with the rear heat sink extended outside the customer-supplied enclosure. If the modules are mounted entirely inside the
customer supplied enclosure, the full power dissipation is inside the cabinet.
2
The AM50/75-IH are designed to mount entirely inside the customer-supplied enclosure.
Publication 1394-5.0 — May 2000
The power dissipation characteristics of the 1394 system and axis
modules are provided below (use for 480V or 360V input).
Important: Use the power dissipation figures shown below to
System Modules
The power dissipation (in watts) of the system module types is shown
below.
% of Rated Power Output
20
40
60
80
100
Axis Modules
The power dissipation (in watts) of the axis modules is shown below:
Total
AM03
AM04
AM07
24
27
33
30
36
48
36
45
63
42
54
78
48
63
93
calculate cumulative system heat dissipation to ensure
that the ambient temperature inside the enclosure does
not exceed 50° C (122° F). To calculate total power
dissipation, add the dissipation of the system module to