8-14
Configuring Your 1394 Analog Servo System
[Language Sel]
Display language for text.
[Ld/Lg Degrees]
If [Ld/Lg Freq] and [Ld/Lg Degrees] are set to
non-zero values, a lead/lag filter (one pole, one
zero) is additionally inserted into the feedback
path of the velocity loop. This filter can be used
to enhance the stability of the loop in the
presence of load resonances.
This parameter specifies the amount of phase
shift that occurs at the lead/lag center frequency.
A negative value specifies a lag, while a positive
value specifies a lead.
In most cases, this filter will not be needed.
[Ld/Lg Freq]
This parameter specifies the center frequency of
the lead/lag filter in the velocity feedback path if
employed (see [Ld/Lg Degrees]. If set to zero,
the filter is disabled.
In most cases, this filter will not be needed.
[Line Voltage]
This parameter selects input line voltage being
used. It affects motor velocity ratings and must
be configured prior to selecting motor types.
This value is set automatically in all Smart Power
22 kW systems and 5 and 10 kW (Series C or
later) systems.
[Max Bandwidth]
After an auto tune, this parameter displays the
maximum system bandwidth that can be
achieved with the machine mechanics.
Publication 1394-5.0 — May 2000
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Default Value
0
Selections
0
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Default Value
0
Selections
0
1
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Linkable
4
Linear List
None
Read/Write
Yes
No
English
English
144, 145, 146, 147
Vel Loop Tune
degs
Read/Write
Yes
No
-50 (lag) degs
+50 (lead) degs
0 degs
148, 149, 150, 151
Vel Loop Tune
Hz
Read/Write
Yes
No
0 Hz
200 Hz
0 Hz
9
Configuration, Setup
None
Read/Write
Yes
No
460 Volts AC
460 Volts AC
380 Volts AC
304, 305, 306, 307
ATune Config
Hz
Read Only
No