AB Quality Allen-Bradley 1394 User Manual page 162

Digital ac multi-axis motion control system
Table of Contents

Advertisement

8-26
Configuring Your 1394 Analog Servo System
[Enble Input Mode]
This parameter specifies whether the hardware
enable signals are used on the wiring board for
input. If configured as Not Used, the HIM or
SCANport device will provide the enable signal
for the axis.
[Vel Command]
Present velocity command for the axis (after all
limiting has occurred).
[Vel Damp Sel]
This parameter is associated with the auto tune
function and specifies the velocity damping
desired by the user. The auto tuning procedure
calculates a new set of Velocity Loop Gains and
a new Current Rate Limit when the user initiates
the Auto Tune Calculate function.
[Vel Feedback]
Present velocity feedback for the axis (after all
filtering has occurred).
[Vel Lim]
This parameter automatically changes both
[CW/CCW Vel Lim] to the same value. (for
convenience during commissioning).
[Vel LowPas BW]
Specifies the single pole low pass velocity
feedback filter bandwidth. A value of 0 disables
the filter.
Publication 1394-5.0 — May 2000
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Default Value
0
Selections
0
1
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Linkable
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Default Value
0
Selections
0
1
2
3
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Linkable
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
24
Setup
None
Read/Write
Yes
No
"Used"
"Used"
"Not Used"
220, 221, 222, 223
Monitor Parms, Vel Cmd Data
rpm
Read Only
No
256, 257, 258, 259
ATune Config
None
Read/Write
Yes
No
"Zeta=0.87"
"Zeta=0.87" Underdamped
"Zeta=1.00" Critically Damped
"Zeta=0.70" Underdamped
"Zeta=1.40" Overdamped
224, 225, 226, 227
Monitor Parms, Vel Cmd Data
rpm
Read Only
No
120, 121, 122, 123
Velocity Cmd Data
rpm
Read/Write
Yes
No
0.0 rpm
8000.0 rpm
This is determined by the motor catalog number.
140, 141, 142, 143
Vel Loop Tune
Hz
Read/Write
Yes
No
0 Hz
1500 Hz
0 Hz