AB Quality Allen-Bradley 1394 User Manual page 68

Digital ac multi-axis motion control system
Table of Contents

Advertisement

3-22
Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
51 mm
1
(2.0 in.)
22 mm
1
(.875 in.)
Motor
cable
Cable Preparation
Publication 1394-5.0 — May 2000
Important: To improve the bond between the motor cable shield
Figure 3.14
Series C Axis Module Cable Clamp
Cable wires
Bracket
screw
Braided
shield
Clamp
exposed
screw
1
Dimensions given are approximate and will vary
depending on the specific installation. Keep wires
as short as possible while maintaining adequate
stress relief.
2. Prepare one end of the motor cable for attachment to the cable
shield clamp by removing the outer insulation and braided shield
from the motor cable. Ensure approximately 51 mm (2.0 in.) of
the insulated cable wires are exposed (refer to Figure 3.14).
3. Remove another 22 mm (.875 in.) of insulation to expose the
braided shield underneath for clamp attachment.
Important: When cutting into the insulation use care not to cut
4. Position the cable shield clamp over the exposed braided shield
(ensure clamp screw is behind clamp and not braided shield).
5. Tighten the clamp screw.
Important: Do not overtighten the clamp screw or damage to
6. Thread the bracket screw into the bottom of the axis module and
tighten.
7. Connect an axis module connector kit (catalog number 1394-199)
to each motor cable that you will use. Refer to instructions that
come with the kit for the specific connections.
and the axis module PE ground, a cable shield clamp
is included with the Series C axis modules.
Cable
shield
clamp
Feedback
cable clamps
System module
Clamp Attachment
into the braided shield underneath.
the braided shield may result.
ground bar
Wiring to Axis Module
Axis
cable clamp
1394 front view

Advertisement

Table of Contents
loading

This manual is also suitable for:

Allen-bradley 1394-dim

Table of Contents