A-4
Specifications
The:
Frequency
Voltage
Current
Operating Temperature
Vibration
Humidity
Weight
Power Loss
Roxburgh Catalog No.
Publication 1394-5.0 — May 2000

DC Link Module

The table below lists the specifications for the DC Link Module.
The:
Firmware version
Software
Input voltage
Current
Capacitance
Energy storage
Cables available (part numbers)
Cable lengths available
Operating temperature
Relative humidity
Weight

Drive Interface Module

The table below lists the specifications for the Drive Interface
Module.
The:
Firmware version
Software
Input voltage
Analog output information
(P x -1,2)
Voltage
Signal isolation
Resolution
Impedance
Offset
Drive OK
Drive enable output
Operating temperature
Relative humidity
Weight

Filters

The table below shows the requirements for filters that you can use.
For the SP-74102-006-01 is:
50/60 Hz
460V AC
°
°
23A @ 50
C (73.4
F)
°
°
°
°
-25
to 85
C (-13
to 185
F)
10-200 Hz @ 1.8 g
90%
1.6 kg (4.16 lb)
20W
MIF323-GS
For the 1394-DCLM is:
5.0 or higher with 1394 x -SJT xx -A systems
3.7 or higher with 1394 x -SJT xx -C- xx and -T- xx systems
3.9 or higher with 1394C-SJT xx -L- xx systems
GML Commander, version 4.02 or higher
530/680V DC, single phase
Continuous (rms) 32A, Peak (rms - 1 second) 200A
990 µF
7.36 joules based on a nominal 50V bus delta
1394-CPDC-0015 and 1394-CPDC-0030
1.5 m (4.92 ft) or 3 m (9.84 ft)
0° to 50° C (32° to 122° F)
5-95%, non-condensing
4.8 kg (10.5 lbs)
For the 1394-DIM is:
3.7 or higher with 1394 x -SJT xx -C- xx and -T- xx systems
3.9 or higher with 1394C-SJT xx -L- xx systems
GML Commander, version 4.01 or higher
24V, 50 kHz provided by the 1394 x -SJT- xx system module
0 to ± 10V analog
1500V rms
12 bits, 4.88 mV
220 ohms
± 80 mV maximum, compensated to 0 through software setup
15V DC @ 5 mA supplied by the DIM
30V DC @ 1 A
0° to 50° C (32° to 122° F)
5-95%
3 kg (6.6 lb)
For the SP-74102-006-02 is:
50/60 Hz
460V AC
°
°
30A @ 50
C (86
F)
°
°
°
°
-25
to 85
C (-13
to 185
F)
10-200 Hz @ 1.8 g
90%
2.7 kg (7.02 lb)
38W
MIF330-GS
For the SP-74102-006-03 is:
50/60 Hz
460V AC
°
°
75A @ 50
C (122
F)
°
°
°
°
-25
to 85
C (-13
to 185
F)
10-200 Hz @ 1.8 g
90%
5.2 kg (13.52 lb)
57W
MIF375-GS