Terminal Block Locations For A 22 Kw System Module - AB Quality Allen-Bradley 1394 User Manual

Digital ac multi-axis motion control system
Table of Contents

Advertisement

3-16
Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
Wire:
Description:
24V Logic
A user-supplied 24V AC rms or 24V DC power source. Refer to
Appendix A for 24V input power specifications.
360/480V AC power input 360/480V AC, three-phase power input. Refer to Appendix A for
system specifications for rated AC input voltage, tolerance, and
source impedance.
Input Power Neutral
Three-phase input neutral (present only on grounded power
configurations).
PE Ground
The1394's ground connection to the bonded system ground bar
on the subpanel.
External Shunt Module
Used to dissipate excess regenerative energy from the system
module.
Publication 1394-5.0 — May 2000

Terminal Block Locations for a 22 kW System Module

All 22 kW system module components use IEC terminals for power
connections. You will wire the system and axis modules using the
power terminal block conveniently located at the bottom front of the
system and axis modules. To gain access to the input power terminals,
open the system module door and look in the lower right corner.
Figure 3.12 details the order of the terminal blocks.
ATTENTION: To avoid personal injury and/or
equipment damage, ensure installation complies with
!
specifications regarding wire types, conductor sizes,
branch circuit protection, and disconnect devices. The
National Electrical Code (NEC) and local codes
outline provisions for safely installing electrical
equipment.
Figure 3.12
Terminal Block for 22 kW System Module
Note:
Refer to Appendices A and B for information about three-phase
input fusing and circuit breaker information as related to the
power input. Refer to the section Connecting Your Shunt
Module for information about wiring the shunt module to the
22 kW system module.
Connects to
Maximum wire size:
terminal(s):
2
3.3 mm
(12 AWG)
W1 and W2
2
U, V, and W
8.4 mm
(8 AWG)
2
System ground bar
8.4 mm
(8 AWG)
(Series A and B)
PE (Series C)
2
PE (Series A and B)
8.4 mm
(8 AWG)
System module ground
bar (Series C)
2
DC+ and COL
8.4 mm
(8 AWG)
Required
(Y/N):
Y
Y
N
N
Y
Y
Y