[Mtr Inertia]
Inertia of motor attached to drive. Automatically
changed when [Motor Type] is changed (to motor
is inertia + 20% for coupling) (Inertia is defined
as time in milliseconds required to reach 1000
rpm at rated motor current). It is used as input to
the auto tune procedure.
Note: Before making modifications to Mtr Data
parameters, [Motor Type] must be set to "custom
motor".
[Mtr Peak Cur]
Motor peak current.
Note: Before making modifications to Mtr Data
parameters, [Motor Type] must be set to "custom
motor".
[Mtr Pole Cnt]
The number of electrical poles on the motor.
Note: Before making modifications to Mtr Data
parameters, [Motor Type] must be set to "custom
motor".
[Mtr Rated Cur]
Motor nameplate rated current. Automatically
changed when [Motor Type] is changed. This
value will be clamped to the current rating of the
axis module if the motor rating is larger than the
module.
Note: Before making modifications to Mtr Data
parameters, [Motor Type] must be set to "custom
motor".
[Neg Cur Lim]
The maximum allowable negative motor current
that can be commanded is specified through this
parameter. If greater than [Bridge Lim], then
[Bridge Lim] will set the limits.
Important: Setting this parameter to a value other
than default will limit motor output torque in CCW
direction.
For Example: If the value equals 100%, the axis
module will not deliver more than 100% to motor,
thus peak torque is limited to 100%.
Configuring Your 1394 Analog Servo System
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
Parameter Numbers
Parameter Group
Display Units
Parameter Type
Change While Running
Linkable
Minimum Value
Maximum Value
Default Value
108, 109, 110, 111
Mtr Data
msec
Read/Write
Yes
No
0 msec
500 msec
100 msec
124, 125, 126, 127
Mtr Data
amps
Read/Write
No
No
0 %
300 %
Rated motor peak current
396
Mtr Data
None
Read/Write
No
No
2
8
This is determined by the motor catalog number.
104, 105, 106, 107
Mtr Data
amps
Read/Write
No
No
0%
100%
0%
188, 189, 190, 191
Torq Data
amps
Read/Write
Yes
No
10% rated motor current
300% rated motor current or 2 times drive rating
(whichever is less)
300% rated motor current
8-17