Chapter 5 Performing An Initial System Diagnosis; Connecting The System Management Terminal To The Chassis - Fujitsu ORACLE M10-1 Installation Manual

Hide thumbs Also See for ORACLE M10-1:
Table of Contents

Advertisement

Chapter 5
Performing an Initial System Diagnosis
This chapter describes the procedures for connecting the system management
terminal, turning on the input power, and checking components.
For details on the XSCF commands executed in each step, see the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 XSCF Reference Manual.

Connecting the System Management Terminal to the Chassis

Turning On the Input Power and Starting the XSCF
Logging In to the XSCF
Checking the XCP Version
Checking the Altitude Setting
Checking the Time Setting
Performing a Diagnosis Test
Checking the Component Status
5.1
Connecting the System Management
Terminal to the Chassis
This section describes the procedures for checking the terminal software settings of
the system management terminal and connecting the system management terminal
to the serial port of the XSCF unit.
1.
Table 5-1     Terminal software setting value
Setting item
Baud rate
Data length
Parity
Confirm that the terminal software for connecting the system management
terminal has the following setting values.
Value
9600
8 bits
None
79