Installation Area For A General Rack - Fujitsu ORACLE M10-1 Installation Manual

Hide thumbs Also See for ORACLE M10-1:
Table of Contents

Advertisement

Handling cables inside the rack
For maintenance work on the SPARC M10-1 and its expansion with optional
components, the chassis may be pulled out from the front of the rack. If the chassis
is mounted in a third-party rack, the cable management arm may not be attached
to the rack. Even if it is attached, it may not function normally. If the cable
management arm is not attached, the chassis cannot be pulled out from the rack as
is with cables connected. In such cases, power off the chassis and then disconnect
the cables. After that, pull out the chassis.
Other conditions
In addition to structural conditions, the following condition must be taken into
consideration.
- Install the rack such that the temperature inside the rack meets the temperature
2.4.2

Installation area for a general rack

Service areas
Service area requirements vary depending on the rack used.
When mounting each chassis in the designated rack, see the examples of service areas
in
Figure 2-3
When using a rack other than the designated rack, see the manual for the rack used.
conditions for cooling the chassis when mounted in the rack. For details, see
Checking Environmental
from the chassis does not re-enter the chassis through the air intakes. This
requires measures such as covering the front and rear of empty spaces inside the
rack.
and
Figure
2-5. The rack width depends on the rack used.
Conditions." Particularly, make sure that exhaust
Chapter 2 Planning and Preparing for System Installation
"2.5
17