[Remote output]
4.
The on/off data of the CPU device set with the automatic refresh parameters is stored in the
"remote output RY" buffer memory.
5.
Remote output RY of the intelligent device station is automatically set to on/off (for each link scan)
according to the output status stored in the "remote output RY" buffer memory.
Programmable
controller CPU
[Remote output RY when the AJ65BT- D75P2-S3 is set to station number 1]
Address
RY01
RY0F
RY10
RY11
RY12
RY13
RY14
126
4)
Y
Signal direction: AJ65BT-D75P2-S3  Master module
Master station
Remote output RY
RY0F to RY00
RY1F to RY10
RY2F to RY20
RY3F to RY30
5)
RY4F to RY40
RY5F to RY50
RY6F to RY60
RY7F to RY70
RY8F to RY80
to
to
RY7FF
RY7F0
Description
Use prohibited
Single-axis positioning start
Dual-axis positioning start
Use prohibited
Single-axis stop
Dual-axis stop
Intelligent device station
(Station number 1:
occupies 4 stations)
Remote output RY
Handshaking signals such
as positioning start
RY0F to RY00
RY1F to RY10
RY2F to RY20
RY3F to RY30
RY4F to RY40
RY5F to RY50
RY6F to RY60
RY7F to RY70