Processing at completion of the G(P).RLPASET instruction
Parameter setting change
Parameter change instruction
G(P).RLPASET instruction
Control data
Device station setting data
Send, receive and automatic refresh buffer assignment data
*1 Set the station number in hexadecimal. (Example) Set 14
232
Performs abnormal completion processing
for station No. 20.
H
Turn the parameter setting instruction off.
Instruct to refresh at normal completion
of the G(P).RLPASET instruction.
Instruct to start the control program at
normal completion of the G(P).RLPASET
instruction.
Instruct to stop data link
Turn the data link stop instruction off
Instruct to stop refreshing
Instruct to change parameters
Clear complete status
Device station setting data/send, receive
and automatic refresh buffer assignment
data: Valid
Number of connected modules involved
in communication: 3
Number of retries: 3 times
Number of automatic return modules:
1 module
Operation specification when CPU is
down: Stop
Scan mode specification: Asynchronous
Delay time setting: 0
First:
Local station, occupies 1 station,
*1
station number 1
Second:
Remote I/O station, occupies 1 station,
station number 2
Third:
Remote I/O station, occupies 1 station,
station number 3
First (station number 1) local station
Send buffer: 100 word
First (station number 1) local station
Receive buffer: 100 word
First (station number 1) local station
Automatic refresh buffer: 0 word