Mitsubishi Electric L26CPU-BT User Manual page 419

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Number
Name
SW000B
Dedicated instruction
(60B
)
retry count setting
H
SW0014
(614
)
H
SW0015
(615
)
Specification of
H
remote device station
SW0016
to be initialized.
(616
)
H
SW0017
(617
)
H
SW0020
Module status
(620
)
H
SW0041
Data link restart
(641
)
result
H
Refresh instruction at
SW0043
standby master
(643
)
H
switching result
SW0045
Data link stop result
(645
)
H
Temporary error
SW0049
invalid station
(649
)
H
specification result
Temporary error
SW004B
invalid station
(64B
)
specification cancel
H
result
SW004D
Loop test result
(64D
)
H
Automatic CC-Link
SW0052
startup execution
(652
)
H
result
Master station
SW0057
duplication error
(657
)
H
canceling result
Description
Set the number of retries for use of dedicated instructions.
Default value: 0 (No retry)
Setting range: 0 to 7 (times)
When the set value is out of the range, 7 is applied.
Specifies the station to be initialized using the information saved in initialization
procedure registration.
0: Initial processing not performed
1: Initial processing performed
b15
b14 b13 b12 b11 b10 b9
SW0014
16
15
14
13
12
11
SW0015
32
31
30
29
28
27
SW0016
48
47
46
45
44
43
SW0017
64
63
62
61
60
59
Numbers 1 to 64 in the above table indicate the station numbers.
The stations need not be set by the number of occupied stations.
Error invalid stations, reserved stations and any station of the number higher than the
max. are not specified.
Stores the status of communication between the L series master/local module and
CPU module.
0: Normal
Other than 0: Stores an error code (Refer to the user's manual for the CPU module
used.)
Stores the execution result of the data link restart instruction with SB0000.
0: Normal
Other than 0: Stores an error code (refer to
Indicates the execution result of refresh instruction at standby master switching.
0: Normal
Other than 0: Stores an error code (refer to
Stores the execution result of the data-link stop instruction with SB0002.
0: Normal
Other than 0: Stores an error code (refer to
Indicates the execution result of temporary error invalid station specification.
0: Normal
Other than 0: Stores an error code (refer to
Indicates the execution result of the temporary error invalid station specification
cancellation.
0: Normal
Other than 0: Stores an error code (refer to
Indicates the execution result of the loop test.
0: Normal
Other than 0: Stores an error code (refer to
Stores the system configuration check result when a new station is added to a system
using an automatic CC-Link startup.
0: Normal
Other than 0: Stores an error code (refer to
Stores the execution result of the master station duplication error canceling request.
0: Normal
Other than 0: Stores an error code (refer to
b8
b7
b6
b5
b4
b3 b2
10
9
8
7
6
5
4
3
26
25
24
23
22
21
20
19
42
41
40
39
38
37
36
35
58
57
56
55
54
53
52
51
Page 358, Section 15.3).
Page 358, Section 15.3).
Page 358, Section 15.3).
Page 358, Section 15.3).
Page 358, Section 15.3).
Page 358, Section 15.3).
Page 358, Section 15.3)
Page 358, Section 15.3)
APPENDICES
Availability
(: Available, : Not
available)
Online
Offline
Master
Local
station
station
b1
2
1
18
17
34
33
50
49
A
417