CHAPTER 12 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL STATIONS
12.3.4

Creating a program

This section shows the program to be used for communication between the master and local stations.
The following diagram shows the relationship between the devices of the master station programmable controller CPU
and the devices of the local station programmable controller CPU.
The shaded areas indicate the devices that are actually used.
[Remote input (RX) and remote output (RY)]
Master station
Master station
programmable
Ver.1 compatible
controller CPU
buffer memory
X100F to X1000
RX00F to RX000
X101F to X1010
RX01F to RX010
X102F to X1020
RX02F to RX020
X103F to X1030
RX03F to RX030
X104F to X1040
RX04F to RX040
X105F to X1050
RX05F to RX050
X106F to X1060
RX06F to RX060
X107D to X1070
RX07F to RX070
Y100F to Y1000
RY00F to RY000
Y101F to Y1010
RY01F to RY010
Y102F to Y1020
RY02F to RY020
Y103F to Y1030
RY03F to RY030
Y104F to Y1040
RY04F to RY040
Y105F to Y1050
RY05F to RY050
Y106F to Y1060
RY06F to RY060
Y107D to Y1070
RY07F to RY070
Ver.2 compatible
buffer memory
X150F to X1T500
RX08F to RX080
X151F to X1510
RX09F to RX090
X152F to X1520
RX0AF to RX0A0
X153F to X1530
RX0BF to RX0B0
X154F to X1540
RX0CF to RX0C0
X155D to X1550
RX0DF to RX0D0
Y150F to Y1500
RY08F to RY080
Y151F to Y1510
RY09F to RY090
Y152F to Y1520
RY0AF to RY0A0
Y153F to Y1530
RY0BF to RY0B0
Y154F to Y1540
RY0CF to RY0C0
Y155D to Y1550
RY0DF to RY0D0
The last two bits cannot be used for communication between the master and local stations.
Ver.1 compatible local station
(station number 1: occupies 4 stations)
Local station
programmable
controller CPU
RY00F to RY000
Y100F to Y1000
RY01F to RY010
Y101F to Y1010
RY02F to RY020
Y102F to Y1020
RY03F to RY030
Y103F to Y1030
RY04F to RY040
Y104F to Y1040
RY05F to RY050
Y105F to Y1050
RY06F to RY060
Y106F to Y1060
RY07F to RY070
Y107D to Y1070
X100F to X1000
RX00F to RX000
X101F to X1010
RX01F to RX010
X102F to X1020
RX02F to RX020
X103F to X1030
RX03F to RX030
X104F to X1040
RX04F to RX040
X105F to X1050
RX05F to RX050
X106F to X1060
RX06F to RX060
X107D to X1070
RX07F to RX070
Ver.2 compatible local station
(station number 5: occupies 2 stations: double)
Local station
Ver.1 compatible
programmable
buffer memory
controller CPU
Y100F to Y1000
RY00F to RY000
Y101F to Y1010
RY01F to RY010
Y102F to Y1020
RY02F to RY020
Y103F to Y1030
RY03F to RY030
RY04F to RY040
Y104F to Y1040
RY05F to RY050
Y105F to Y1050
RY06F to RY060
Y106F to Y1060
RY07F to RY070
Y107D to Y1070
X100F to X1000
RX00F to RX000
X101F to X1010
RX01F to RX010
X102F to X1020
RX02F to RX020
X103F to X1030
RX03F to RX030
X104F to X1040
RX04F to RX040
X105F to X1050
RX05F to RX050
X106F to X1060
RX06F to RX060
X107D to X1070
RX07F to RX070
Ver.2 compatible
buffer memory
RY06F to RY060
Y150F to Y1500
RY07F to RY070
Y151F to Y1510
RY08F to RY080
Y152F to Y1520
RY09F to RY090
Y153F to Y1530
RY0AF to RY0A0
Y154F to Y1540
RY0BF to RY0B0
Y155D to Y1550
RX06F to RX060
X150F to X1500
RX07F to RX070
X151F to X1510
RX08F to RX080
X152F to X1520
RX09F to RX090
X153F to X1530
RX0AF to RX0A0
X154F to X1540
RX0BF to RX0B0
X155D to X1550
12