(b) G(P).RIWT instruction
OT + LS  [BC + {(write points + 16) / 16}
OT
Processing time of LCPU dedicated instructions: 0.5 [ms]
LS
Link scan time (refer to
BC
Constant
Transmission
156kbps
speed
BC
SL
Target station sequence scan time
(0 when writing buffer memory in the CC-Link)
WT
Monitoring time set in SW0009 (refer to
RT
Number of retries set in SW000B (refer to
When the programmable controller CPU type is L26CPU-BT, the transmission speed is 10 Mbps, the link
scan time is 5 ms, the write points are 20 words (buffer memory in the CC-Link), the monitoring time is 10
s, and the number of retries is zero.
OT + LS  [BC + {(write points + 16) / 16}
= 0.5 + 5  [12 + {(20 + 16) / 16}
= 0.5 + 5  [12 + {3  1.067}] + 0
= 76.505
= 76.5 [ms]
*1
Round up below the decimal point
*2
Time elapsed when retries of a dedicated instruction occur
*1
 1.067] + SL + (WT  RT  1000)
Page 430, Appendix 4.1.)
625kbps
6
7
Page 416, Appendix 3.2.)
*1
 1.067] + SL + (WT  RT  1000)
*1
 1.067] + 0 + (10  0  1000)
*2
[ms]
2.5Mbps
5Mbps
9
11
Page 416, Appendix 3.2.)
APPENDICES
A
10Mbps
12
451